FEATURES |
A Synthesis of the Best Technologies
|
Easy Maintenance
|
|
- True Online Double Conversion design
- Perfected lit proven design to work in extreme power conditions
- High efficiency, Low running cost (24 x 7 operation) |
- Automatic bypass
- Hot swappable batteries |
Displays necessary information of UPS,
- Input Voltage,
- Heat sink temp,
- DC / Battery Voltage,
- Output Voltage,
- Output Frequency
- Output current
Indicates and annunciates eight different alarm conditions like;
- Input under Voltage,
- Output overload,
- Battery low etc.
The LED indications on the fascia provides UPS status at a glance.
|
|
|
Power Friendly
|
Advanced Communication Interface
|
- State-of-the-Art PWM rectifier with inbuilt APFC
- Near unity power factor
- Controlled input harmonic level
- Wide input Voltage window |
- Flexibility at an interface level
- UPSMON 11*
-
software solution for Data, Event monitoring
- Auto shut down from remote places - SNMP compliant*
- BMS compliant*
- Ease of operation
- Easy to install
- User friendly digital display
|
|
Robust Charger, Longer Backups
|
- Robust battery charger to charge the batteries quickly for longer backup duration
- Advance battery management |
|
Superior Output Power Quality
|
Well Protected Load |
|
- Dual Microprocessor controlled, IGBT based
Inverter, a synthesis of best technologies
- Low distortion on full non-linear loads
- Superior static lit dynamic regulation |
- Protected against abnormal input conditions
- Against short circuit, overload, over / under Voltage |
|
|
|
|
High Reliability
|
Compliance to International standards
|
|
- Designed lit Manufactured in accordance with ISO 9001 : 2000
- Complied with testing standard IEC 62040 Part III |
- Complied to International standards on EMC / EMI |
|
|
|
|
Model |
LNux 110 |
Rating ( in kVA ) |
3, 5, 6 kVA |
Input Voltage |
230 V (-30% to +20%) 1 Ph & N |
Input Power Factor |
Near Unity |
Battery Voltage |
192 V DC |
Output Power |
3 kVA / 2.4 kW, 5 kVA / 4 kW, 6 kVA / 4.8 kW |
Output Voltage
|
230 V (± 1%) 1 Ph lit N |
Output Frequency |
50 Hz nominal (± 0.25 Hz in free running mode) |
Total Harmonic Distortion |
< 3% on linear load, < 5% on non-linear load ( Ref. IEC 62040 Part III ) |
Overall Efficiency |
upto 90% |
| Transient Response |
Complies to IEC 62040 Part III Class 1 |
Overload Capacity |
125% for 10 minutes; 150% for 60 see ( Inverse time characteristics ) |
Acoustic Noise Level |
< 50 dbA @ 1 m |
| Communications Interface |
RS 232 |
Automatic Bypass |
Integrated |
Cooling |
Forced air |
Ambient Temp |
0 to 40°C |
Relative Humidity |
Upto 90% Rh, Non condensing |
Panel Dimensions (in mm) (W x D x H) |
3 kVA 225 x 550 x 600
5 lit 6 kVA 225 x 700 x 600 |
|